Griffin installed a deep well system capable of pumping 1,500 GPM. The deep well system was drilled to 50 ft. below ground and equipped with 5hp pumps. Additionally, a wellpoint system was installed temporarily to accommodate a design change. Finally, the entire system was powered by the electrical service from adjacent property to eliminate the need for a temporary generator.